Ruud Furnace Code 57



This Rheem Classic 90 Plus troubleshooting guide is a go-to solution if your furnace stops working. The goal of this guide is to help identify the problem and find the best solution. Keep in mind that it is NOT a Do-it-Yourself guide. It is useful in case of an emergency, only when an experienced service member is not available.

The Rheem Gas furnaces are energy efficient units, designed to work for a long time. The heat exchanger made of stainless and aluminized steel provides corrosion resistance. Moreover, the blower section is insulated to decrease noise. There is also a direct spark mechanism ignites the Rheems furnace pilot light, for quick lighting.

  1. For a Ruud Ultra UGFD series gas furnace with seven segment LED diagnostics, error code 57 refers to a problem at the High Pressure Switch HPS. It means the Draft Inducer DI is working, the HPS contacts are open and as a result the Igniter is not activating, so no heat is generated.
  2. Gas Furnace Troubleshooting and Repair - Flash Codes. Nearly every manufacturer has different flash codes. Within the manufacturers, the flash codes can be different from one furnace to the next. Therefore, it is nearly impossible to describe every flash code event for every furnace for every manufacturer.

Code Description; 0: Standby: C: Compressor on (cooling or heat-pump heat) H: Gas heat on: F: Continuos fan on: 10: 1 hour lockout: 11: Failed ignition: 12: Low flame. Please note, the following Ruud Repair guide is for informational purposes only. Any servicing you attempt is at your own risk. Amana is regularly recognized as the maker of some of the most energy-efficient furnaces on the market, with many of their units receiving ENERGY STAR® certification. Winnipeg, MB R2W 3P6 Phone: 204-888-2020 Text Message: 204-888-0202.

Our Favorite Rheem Gas Furnaces

No products found.

Rheem Classic 90 Plus Furnace – Common Issues

Common issues you may encounter during the Rheem Classic 90 Plus troubleshooting.

Periodically perform standard maintenance to ensure the furnace operates satisfactorily for years. Always clean your unit before starting it for the winter season.

Ruud furnace error code 57
  • The first common issue is the Furnace is not putting out heat. The furnace is turned on, and you hear it working, but there is no heat coming out of the vents.
  • The furnace is not igniting. You push on the igniter, and it will not ignite the unit.
  • The heater is running all the time even when you lower the set point. It does not seem to stop running or shut off when it reaches the setpoint.
  • The unit is running hotter than normal. When you touch the housing, you feel it is hot to the touch.
  • The unit is heating certain rooms and not others. Some rooms do not get any heat while others are comfortably warm.
  • The gas bill is running exceptionally high compared to the average winter usage. The gas company is sending you notices of your higher energy consumption.
  • You see too much Soot or detect a strong gas smell.

Tools You Will Need

Caution: before you start the troubleshooting, turn off the furnace. Unplug from the power supply and remove the control door. Allow the gas in the lines to clear by turning off the gas control switch and wait 5 minutes. Make sure you do not smell any gas. If you detect a strong gas smell, stop and leave your house. Immediately contact the local fire department and your gas company.

To effectively fix the common problem, you will need the following tools:

  • A ¼ inch or a 5/16 inch nut driver or a bit
  • a cordless drill used to service the parts
  • An insulated handle screwdriver
  • A handheld vacuum
  • A Multi-Meter used to test the Thermocouple.

No products found.

Rheem Classic 90 Plus Furnace Troubleshooting

Please follow this Rheem Classic 90 Plus troubleshooting guide to fix common problems.
Some of the troubleshooting tips that might save you time are as listed below.

1. Power

One of the most overlooked issues is Power. Always check that your furnace is plugged into the wall outlet and turned on. Check to see if the thermostat setpoint is higher than the indoor temperature. Press the reset button, no more than twice to reset the unit. If there is no power coming into the unit then, reset the circuit breaker if it was tripped off. Replace fuses with broken wires or if they turned black.

2. Thermostat Batteries

Check the thermostat batteries and replace them when necessary.

3. The Furnace

If you there is no heat out of the unit and no gas smell, then, turn off the furnace. Unplug from the power supply and remove the control door. Turn off the gas control switch and wait 5 minutes then remove the filter from the front panel. Replace the filter or remove the accumulated dirt and debris with a hand-held vacuum. Clean the filter with warm water and a few drops of dishwashing liquid. Rinse and air-dry thoroughly before inserting it in the furnace. Turn the switch to “On” position and close the control door. Turn on the furnace power.

4. The Igniter

If the igniter not on, then relight the pilot if it was turned off. Clean around the pilot light if it does not light and dry up any water. Use an insulated handle screwdriver to test the transformer. Check if the current arches when it touches one of the contacts. Replace the transformer if the current is weak. Replace any corroded or broken wires and electrodes.
Change the pilot thermocouple if all the previous items check.

5. The Combustion Chamber

If the unit is running hot, place your hand near the door of the combustion chamber. If it is hot, then the system has a blockage. Clean the chimney, the duct pipe, and the combustion chamber. Check and replace the heat exchanger and gaskets if broken.

6. The Vent

Check when the heat comes on if it heats up certain rooms only. If so, place your hand on each room’s vent and, if you don’t feel any airflow coming out of those vents, then clean their ducts. Replace any crushed or broken exterior piping. Clear any obstruction from interior vents.

7. Replacing the Thermostat

If your heater is running all the time even when you lower the setpoint, then replace the thermostat.

8. Efficient Appliances

If your gas bill is higher than your average, then you may have added an inefficient appliance. It may increase your energy usage.

Ruud Furnace Code 57

9. Emergency Advice

If you see Soot or smell gas, immediately turn off your furnace and leave the house. Call the fire department or the local gas company. Return home when you get a clear communication that it is safe to return.

Caution Notes

Rheem Error Code 57

Immediately turn off your furnace if you smell gas. Contact your gas company or the fire department and leave the house. Do not enter your home until you receive the clear signal.
Keep all combustible material away from the unit.
Remain clear of heat sources while performing the Rheem Classic 90 Plus troubleshooting.

Be aware of dust and allergens while cleaning your filter. Please use precautions if you have any respiratory issue.
Immediately, contact your physician if you experience a severe allergic reaction. Or go to the nearest emergency room if you have difficulty breathing or swelling of the tongue.

Conclusion

We hope the Rheem Classic 90 Plus troubleshooting guide shed light on problems your furnace may encounter. And the recommended fixes needed during its lifetime. If you find this information helpful, leave us a comment in the section below. We welcome your feedback and value your input.

Images sources: 1, 2

Related Posts

Error code Cis 'no ignition' Ensure you have gas to the appliance. Error is malfunction of operational switch: press max or mim button on PC boar. Rheem Integrity not always lighting.

Feb 20- rheem integrity is flashing - C- Rheem Tankless Hot Water. This kind of error code can be air in gas line, improper grounding at . Get free help, tips support from top experts on rheem cerror code related issues. Error is malfunction of operational switch: press max or mim button on PC boar or replace PC board.

An official Rheem error codes list and troubleshooting steps to take. No Ignition, Ensure you have gas to the appliance. Malfunction of Operational Switch, Press max button on PCB to reset. Contact Rheem via the phone number in your owners manual and they will send you an page . Includes Indoor, Outdoor and Heavy Duty Models. Technical Competence, Product Confidence.


Paloma's tankless water heaters have a display screen that shows an error code shows an error code when a problem occurs. Remember if you raise the temperature setting, risk is that tankless cannot heat be grounded.

Tankless troubleshooting resources for homeowner Search this . Rheem Water Heaters integrity cRheem Tankless Error Code a class action lawsuit. Troubleshoot-Rheem-Tankless-water-heater.